Brand Name : Goldway
Model Number : GS20
MOQ : 1
Price : 1
Payment Terms : T/T, Western Union, Paypal
Delivery Time : 3-5 Working Days
Packaging Details : By Carton
Product name : PHiliph Goldway
Type : GS20
Warranty : 90days
Voltage : 110V—240v
Minimum purchase commitment : 1 unit
State : In Good Condition
Stock : In stock
Delivery Term : Express delivery
Language : English,French,Italian,Spanish,Japanese,Hindi,etc
Context of Use : ICU, emergency, Patient Monitor, ICU Room and operating room
Function : ECG,SpO2,NIBP,Medical Care,RESP
PHiliphh Goldway GS20 Patient Monitor Bedside Monitor
PHiliphh GOLDWAY GS20 Patient Monitor Bedside Monitor Hospital Medical Equipment In Good Working Condition
►Brief Introduction
The PHiliphh Goldway GS20 Patient Monitor is a medical device used for monitoring vital signs and parameters of patients in healthcare settings. It is designed to display and track various physiological measurements such as ECG (electrocardiogram), blood pressure, SpO2 (oxygen saturation), respiration rate, temperature, and others. The monitor provides real-time data to healthcare professionals for assessing the patient's condition and making treatment decisions. It features a user-friendly interface, customizable alarm settings, and connectivity options for data transfer. The PHiliphh Goldway GS20 Patient Monitor aims to improve patient care by providing accurate and reliable monitoring capabilities.The PHiliphh Goldway GS20 preconfigured patient monitor provides advanced functionalities for various clinical environments and patient acuity levels. In addition to offering market-proven essential parameters, the GS20 system is cost-effective and easy to learn and use.
► Overview
1. The display screen should be flat and without distortion. After powering on, it can clearly display waveforms and digital information, and the clock should run normally.
2 The monitor shall not be mechanically damaged that may affect its operation. All knobs and switches shall be firm and reliable, accurately positioned, clean on the surface, with clear words, symbols and marks, and free of corrosion, coating peeling, obvious scratches, damage and deformation.
3. All components and controls of the monitor should be flexible and reliable in operation, and the fasteners should not be loose.
► Parameter performance
1. ECG monitoring parameter performance meets the requirements of YY 1079-2008
2. Breathing, lead loss and active noise suppression
For any patient electrode connection, the DC current flowing through is <0.1uA when all other patient electrodes are connected to a common node, (i.e., any connection used as input to an amplifier to measure ECG potential). For any other patient electrode connection, this current is <0.9uA.
3. The ability to suppress tall T waves
4. The response time of the heart rate meter to changes in heart rate
5. Suppression of fast ECG signals by the pacing pulse detector
Minimum input slew rate: 0.9V/s.
6. Heart rate measurement range and accuracy
Measuring range:
a. Adult/pediatric: 15bpm~300bpm;
Newborn: 15bpm~350bpm;
b. Accuracy: +1% or +5 bpm, whichever is larger in absolute value. Heart rate display resolution: 1bpm;
c. Heart rate display refresh speed: 1s.
7. Alarm limit range
8. Resolution of alarm limit settings
The resolution of alarm limit setting is 1bpm
9. Alarm mute
The default setting of alarm silence is 1min.
10. Gain
11. Time Base Selection and Accuracy
Scanning speed of ECG waveform: optional 6.25 mm/s, 12.5 mm/s, 25 mm/s, 50mm/s, the error does not exceed +10%
► Product configuration
Product number | ECG | SpO2 | Temperature | NIBP | CO2 |
GS10 | √ | √ | √ | √ | √ |
Pls contact us , if you are interested in PHiliphh GOLDWAY GS20 Patient monitor Bedside Monitor Hospital Medical Equipment In Good Working Condition.
![]() |
PHiliph GOLDWAY GS20 Patient Monitor Hospital Medical Equipment In Good Working Condition Images |